Dean 8070306 Natural Gas Safety Control 3.5" WC Model 7000 BMVR
Specifications:
- Nat Gas Safety, 3.5" Wc, Model 7000 Bmvr, Mfg#700-506
- 3/4" Fpt In X 3/4" Fpt Out, Includes 3/4" X 1/2" Reducer
- Bushings, Millivolt Actuator, Requires Wire Lead
- Thermopile, 36" # 51-1121 Or 60" # 51-1257
- 1/4" Cct Pilot Out, 300,000 Btu
- For Lp Conversion Use # 51-1470
- Bakers Pride Oven Following Models Made After 10/94:
- Y600, Y800, Ds-805, Gs-805, D-125, 101, 151, 201
- 251, 301, 351, 3151, 401, 451, 4151, Fc-(516,616,816)
- Cecilware Fryer Fmp-30, Fmp-40, Fmp-65, Fmp-403, Fms-30,
- Fms-40, Fms-65.
- Frymaster Fryer Models Made Before Feb. 1993: Gf14, Gf40,
- J1C, Jcfx, J3Fc, J65X, Mj15, Mj35, Mj235, Mjcf.
- Imperial Fryer Series: If, Ihr, Ir.
- Keating Fryer Gas Counter Units And Miraclean Griddles.
Description
Dimensions:
- Weight: 2.4 lbs
- Length: 5.7 in
- Height: 3.5 in
- Width: 4.5 in
ATOSA:
BLOOMFIELD:
ENTR?E:
400042-1RS
FRYMASTER:
1896 807-0115 807-0306 807-2428 807-3645 8070114 8070115 8072428 8073645 810-0014 8100014 FM1896 FM807-0115 FM807-0306 FM807-2428 FM8070114 FM8070115 FM8070306 FM8072428 FM810-0014 FM8100014
JADE RANGE:
MARKET FORGE:
U-LINE:
343-701-400 343-811-400 700-506
Step1: Turn off gas supply and electrical power to the unit before servicing.
Step2: Allow appliance to cool completely to avoid burns.
Step3: Remove front or side access panel to reach gas control area.
Step4: Label and disconnect inlet, outlet, and pilot tubing carefully.
Step5: Remove existing safety control valve from mounting position.
Step6: Install new valve, ensuring correct gas flow direction.
Step7: Reconnect all gas lines securely and check for leaks with approved solution.
Step8: Restore gas and power, then test ignition and check better shutdown function.
-
What maintenance is required for the Dean 8070306 Natural Gas Safety Control?
Inspect all gas line connections regularly for leaks and secure fittings. Clean surrounding components to prevent grease or dust interference. Verify proper pressure settings and stable flame operation during service checks. Ensure electrical and sensing terminals remain tight and corrosion-free for better operation.
-
What are common issues with the Dean 8070306 Natural Gas Safety Control?
- Failure to open gas valve due to faulty control signal.
- Inconsistent gas pressure causing weak or unstable flame.
- Delayed ignition or ignition lockout conditions.
- Wiring faults or poor electrical connection at terminals.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More