Tri-Star 300188 Fryer Natural Gas Safety Control Valve 7000 BMVR 3.5" WC
Specifications:
- Nat Gas Safety, 3.5" Wc, Model 7000 Bmvr, Mfg#700-506
- 3/4" Fpt In X 3/4" Fpt Out, Includes 3/4" X 1/2" Reducer
- Bushings, Millivolt Actuator, Requires Wire Lead
- Thermopile, 36" # 51-1121 Or 60" # 51-1257
- 1/4" Cct Pilot Out, 300,000 Btu
- For Lp Conversion Use # 51-1470
- Bakers Pride Oven Following Models Made After 10/94:
- Y600, Y800, Ds-805, Gs-805, D-125, 101, 151, 201
- 251, 301, 351, 3151, 401, 451, 4151, Fc-(516,616,816)
- Cecilware Fryer Fmp-30, Fmp-40, Fmp-65, Fmp-403, Fms-30,
- Fms-40, Fms-65.
- Frymaster Fryer Models Made Before Feb. 1993: Gf14, Gf40,
- J1C, Jcfx, J3Fc, J65X, Mj15, Mj35, Mj235, Mjcf.
- Imperial Fryer Series: If, Ihr, Ir.
- Keating Fryer Gas Counter Units And Miraclean Griddles.
Description
Dimensions:
- Weight: 2.4 lbs
- Length: 5.7 in
- Height: 3.5 in
- Width: 4.5 in
ATOSA:
BLOOMFIELD:
ENTR?E:
400042-1RS
FRYMASTER:
1896 807-0115 807-0306 807-2428 807-3645 8070114 8070115 8070306 8072428 8073645 810-0014 8100014 FM1896 FM807-0115 FM807-0306 FM807-2428 FM8070114 FM8070115 FM8070306 FM8072428 FM810-0014 FM8100014
JADE RANGE:
MARKET FORGE:
TRI-STAR:
400042 AS-300188 TRS300188
U-LINE:
343-701-400 343-811-400 700-506
Step1: Turn off gas fryer supply and disconnect power before servicing unit; ensure ventilation; verify compatibility.
Step2: Remove old valve and clean mounting area; inspect fittings and gas line.
Step3: Install new valve, align inlet/outlet, tighten fittings with proper sealant tape using approved method.
Step4: Reconnect lines, restore gas slowly, check for leaks with soap solution.
Step5: Test ignition and burner operation; ensure safety shutoff works and shutdown safety test.
-
What maintenance is required for the Tri-Star 300188 Safety Control Valve?
Inspect the gas safety control regularly for secure wiring, clean electrical terminals, and proper millivolt response from the thermopile. Check for gas leaks and ensure stable pressure during operation. Keep the valve free from grease buildup and verify accurate ignition and shutoff during service checks.
-
What are common issues with the Tri-Star 300188 Safety Control Valve?
- Gas leakage due to worn seals.
- Inconsistent flame or burner shutdown due to valve blockage.
- Failure to open or close due to thermocouple malfunction.
- Reduced gas pressure affecting heating performance.
Customer Reviews
Write a Review
-
Quick Response
Great quality, works seamlessly with appliances
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More