Vulcan Hart 00-410841-00030 Fryer Combination Valve Natural Gas 24V
Specifications:
- [ Nat Gas ] [ Size 1/2" Fpt ] [ Nat Safety ][ 3.5"Wc ]
- [24Vac/12Vdc] [ Width 3.75" ] [Red & Blue Wires] [ Brand Rs
- Mfg# 700-409 ], 300,000 Btu, Bmser
- For Lp Order #51-1363 Cap & Spring
- 1/4" Cct Pilot Out Only, W/Slotted Thermopile Magnet
- 1/2" X 3/8" Reducer Bushings, Model 7000 Bmser
- For Intermittant Pilot, Direct Spark, And Hot Surface.
- Thermopile, # 51-1122, Screw In Type, 7/16-27
- Brass Pile Holding Nut, 3/8-38 Thread, For Magnet, 750Mv,
- 500Mv Under Load ,
- Frymaster Fryer F45, Mac(51,151,251,351), Mj45, Mj45E.
- Fryer Models Made In Or After Feb. 1993:
- Gf14, Gf40Sd, Mj35, Mj45, Mj235.
- Pitco Rethermalizer Rtg14, Rtg14 (Taco Bell).
- Fryer 12,14,14Bif,14R,14Ufm,18,18Bif,18Ufm,7,Pg14D,Pm14,
Description
Dimensions:
- Weight: 1.9 lbs
- Length: 5.75 in
- Height: 3.5 in
- Width: 4.5 in
FRYMASTER:
HOBART:
PITCO:
U-LINE:
700-409
VULCAN HART:
Step1: Turn off gas and electricity; allow fryer to cool.
Step2: Remove access panel and disconnect old valve noting wiring/gas line layout.
Step3: Install new valve ensuring correct orientation and seal connections.
Step4: Reconnect wiring and gas fittings securely; check for leaks with soapy water.
Step5: Restore power, test ignition, and verify flame stability.
Step6: If any leak or malfunction occurs, shut off supply and contact technician.
-
What maintenance is required for the Vulcan Hart 00-410841-00030 Combination Valve?
Regularly inspect fryer valve for gas leaks and loose connections using proper leak detection solution. Clean debris and ensure proper electrical coil operation with routine testing. Verify calibration and shutoff response for safe fryer performance during maintenance checks.
-
What are common issues with the Vulcan Hart 00-410841-00030 Combination Valve?
- Failure to open due to weak electrical signal or faulty coil.
- Gas leakage from worn internal seals or valve body damage.
- Burner not igniting or inconsistent flame control.
- Safety lockout caused by pressure imbalance or wiring faults.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More